Domain 1: Plumbing License Law and Board Rules

Question 1

A 2-inch hole is proposed through the center of a single 3.5-inch load-bearing wall stud. The opening would remove about 57% of the stud width, while the ordinary bored-hole limit is 40%. No engineered detail is shown. Which instruction is technically sound?

Show answer & explanation

Correct answer: D - Reroute the pipe or use an approved doubled-stud or engineered solution

Domain 2: Definitions

Question 2

During an accessibility inspection, an adult restroom has a water-closet centerline 17 inches from the side wall, an 18-inch seat height, grab bars 35 inches above the floor, and a lavatory rim 35 inches above the floor. Which element must be corrected?

Show answer & explanation

Correct answer: C - Lower the lavatory rim to no more than 34 inches

Domain 3: General Regulations or General Requirements

Question 3

After a check-equipped pressure-reducing valve is installed on a residence, the water heater's T&P valve begins dripping during burner recovery. No expansion tank is present; cold static pressure is 60 psi and rises to 145 psi as the water heats. Which remedy targets the cause rather than the symptom?

Show answer & explanation

Correct answer: B - Install or restore a properly precharged expansion tank

Question 4

A tankless water heater must deliver 4.0 gpm while raising water from 55°F to 120°F. Its thermal efficiency is 90%. Using 500 × gpm × temperature rise for required output, select the minimum input rating after rounding up to the next 1,000 Btu/h.

Show answer & explanation

Correct answer: C - 145,000 Btu/h

Domain 4: Plumbing Fixtures

Question 5

A potable make-up line directly supplies a closed-loop boiler that contains corrosion-treatment chemicals. Boiler pressure can exceed the potable-supply pressure. Which testable backflow assembly is appropriate for this connection?

Show answer & explanation

Correct answer: D - Reduced-pressure principle assembly

Question 6

At a residence, static pressure near the meter is 96 psi. With two showers flowing, pressure at the remote fixture falls to 34 psi. Which interpretation best fits these readings?

Show answer & explanation

Correct answer: A - Regulate the high static pressure, then compare flowing pressures to locate excessive service or distribution loss

Domain 5: Water Heaters

Question 7

A journeyman enters a basement mechanical room and detects a strong propane odor concentrated near the floor. No flame is visible. What is the best immediate response?

Show answer & explanation

Correct answer: B - Leave switches untouched, evacuate, and initiate emergency procedures

Domain 6: Water Supply and Distribution

Question 8

Under 2018 IPC-family values, a horizontal building drain will carry 45 drainage fixture units at a slope of 1/8 inch per foot. The sizing table permits 36 DFU on 3-inch pipe and 180 DFU on 4-inch pipe. What is the minimum permitted drain size?

Show answer & explanation

Correct answer: C - 4 inches

Domain 7: Sanitary Drainage

Question 9

An IPC-family same-story bathroom group uses the lavatory as the dry vent for a 2-inch horizontal wet vent serving the lavatory, bathtub, and water closet. A kitchen-sink branch is then connected into the wet-vented section. Which modification restores a compliant arrangement?

Show answer & explanation

Correct answer: A - Move the kitchen-sink connection outside the bathroom wet-vent section

Domain 10: Fuel Gas or Fuel Piping

Question 10

A Texas Journeyman Plumber with no specialty endorsement is assigned to braze medical-oxygen piping during a hospital remodel under an RMP's supervision. What additional authority is required before the journeyman performs this work?

Show answer & explanation

Correct answer: B - A Texas Medical Gas Piping Installation Endorsement